WiFi
Телефония
Рации
Apple
USB & LAN
SALE

RFS CELLFLEX

базов.:0


M
WMD
WifiMAG
spw
i_te
mark
elko
RFS CELLFLEX
x
0
Под заказ
Артикул:
#0001616
  • Low Attenuation
  • The low attenuation of CELLFLEX coaxial cable results in highly efficient signal transfer in your RF system.
  • Complete Shielding
  • The solid outer conductor of CELLFLEX coaxial cable creates a continuous RFI/EMI shield that minimizes system interference.
  • Low VSWR
  • Special low VSWR versions of CELLFLEX coaxial cables contribute to low system noise.
  • Outstanding Intermodulation Performance
  • CELLFLEX coaxial cable’s solid inner and outer conductors virtually eliminate intermods. Intermodulation performance is also confirmed with state-of-the-art equipment at the RFS factory.
  • High Power Rating
  • Due to their low attenuation, outstanding heat transfer properties and temperature stabilized dielectric materials, CELLFLEX cable provides safe long term operating life at high transmit power levels.
  • Wide Range of Application
  • Typical areas of application are: feedlines for broadcast and terrestrial microwave antennas, wireless cellular, PCS and ESMR base stations, cabling of antenna arrays, and radio equipment interconnects.
  • Характеристики
    Cable TypeFoam-Dielectric, Superflexible
    Size1/2"
    JacketStandard
    Return Loss (VSWR) PerformanceStandard
    Maximum Return Loss, dB (VSWR)Contact RFS for your VSWR performance specification for your required frequency band.
    Impedance, Ohm50 +/- 1
    Maximum Frequency, GHz11.7
    Velocity, percent82
    Peak Power Rating, kW20.5
    Inner Conductor dc Resistance, ohm/1000 m (ohm/1000 ft)2.9 (0.88)
    Outer Conductor dc Resistance, ohm/1000 m (Ohm/1000 ft)3.4 (1.04)
    RF Peak Voltage, Volts1430
    Jacket Spark, Volt RMS5000
    Capacitance, pF/m (pF/ft)82.0 (25.0)
    Inductance, µH/m (µH/ft)0.207 (0.063)
    Outer Conductor MaterialCorrugated Copper
    Inner Conductor MaterialCopper-Clad Aluminum Wire
    Diameter over Jacket Nominal, mm (in)13.7 (0.54)
    Diameter Outer Conductor, mm (in)12.3 (0.48)
    Diameter Inner Conductor, mm (in)3.6 (0.14)
    Diameter Dielectric, mm (in)8.3 (0.33)
    Minimum Bending Radius, Repeated Bends, mm (in)32 (1.25)
    Bending Moment, N•m (lb-ft)1.8 (1.3)
    Cable Weight, kg/m (lb/ft)0.21 (0.14)
    Tensile Strength, N (lb)650 (146)
    Flat Plate Crush Strength, N/mm (lb/in)20.4 (110)
    Recommended / Maximum Clamp Spacing, m (ft)0.30 / 0.30 (1.00 / 1.00)
    Installation Temperature, °C(°F)-40 to +60 (-40 to +140)
    Storage Temperature, °C (°F)-70 to +85 (-94 to +185)
    Operation Temperature, °C(°F)-50 to +85 (-58 to +185)
    Phase StabilizedPhase stabilized and phase matched cables and assemblies are available upon request.
    ApplicationsOEM jumpers, Main feed transitions to equipment, GPS lines

    [+]

    [-]

    up